 319 Electrical Specifications

The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C)

Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.

True rms for ac V and ac A accuracy is specified from 5% to 100% of range.

Environmental Specifications
Operating Temperature

 14°F to 122°F (-10 °C to 50 °C)
Storage Temperature

 -40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity

 Non condensing (< 50 °F) (< 10 °C)

 90 % RH (50 °F to 86 °F) (10 °C to 30 °C)

 75 % RH (86 °F to 104 °F) (30 °C to 40 °C)

 45 % RH (104 °F to 122 °F) (40 °C to 50 °C)

 (Without Condensation)
Operating Altitude

 1 mile (2000 meters) above mean sea level
Storage Altitude

 7 miles (12,000 meters) above mean sea level
IP Rating

 IP40
Vibration Requirements

 Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements

 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC

 Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature Coefficients

 0.1x (specified accuracy)/ °C

 (<64 or=""> 82° F)

 (<18 or=""> 28 °C)
319 Electrical Specifications
Current AC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (50-60 Hz) {40 A}

 2.5% ± 8 digit (60-500 Hz) {40 A}

 1.5% ± 5 digit (50-60 Hz) {600/1000 A}

 2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2  3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response  rms
Current DC
Range  40.00 A, 600.0 A, 1000 A
Resolution  0.01 A, 0.1 A, 1 A
Accuracy  1.6% ± 6 digit (40 A)

 1.5% ± 5 digit (600/1000 A)
Voltage AC
Range  600.0 V
Resolution  0.1 V
Accuracy  1.5% ± 5 digit (20-500Hz)
AC response  rms
Voltage DC
Range  600.0 V
Resolution  0.1 V
Accuracy  1% ± 4 digit
Resistance
Range  400.0 Ω

 4000 Ω
Resolution  0.1 Ω

 1 Ω
Accuracy  1% ± 5 digit
Continuity

 ≤ 30 Ω
Inrush
Integration time  100 ms
Frequency
Range  5.0 - 500.0 Hz
Accuracy  0.5% ± 5 digit
Trigger Level  10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A