Pinza Amperimetrica Fluke 319
319 Electrical Specifications
The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
Environmental Specifications |
Operating Temperature |
|
14°F to 122°F (-10 °C to 50 °C) |
|
Storage Temperature |
|
-40 °F to 140 °F (-40 °C to 60 °C) |
|
Operating Humidity |
|
Non condensing (< 50 °F) (< 10 °C) |
|
90 % RH (50 °F to 86 °F) (10 °C to 30 °C) |
|
75 % RH (86 °F to 104 °F) (30 °C to 40 °C) |
|
45 % RH (104 °F to 122 °F) (40 °C to 50 °C) |
|
(Without Condensation) |
|
Operating Altitude |
|
1 mile (2000 meters) above mean sea level |
|
Storage Altitude |
|
7 miles (12,000 meters) above mean sea level |
|
IP Rating |
|
Vibration Requirements |
|
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
|
Drop Test Requirements |
|
3 ft (1 m) drop test, six sides, oak floor |
|
EMI, RFI, EMC |
|
Instrument unspecified for use in EMC field ≥ 0.1 V/m |
|
Temperature Coefficients |
|
0.1x (specified accuracy)/ °C |
|
(<64 or=""> 82° F)64> |
|
(<18 or=""> 28 °C)18> |
|
319 Electrical Specifications |
Current AC |
Range |
40.00 A, 600.0 A, 1000 A
|
Resolution |
0.01 A, 0.1 A, 1 A |
Accuracy |
1.6% ± 6 digit (50-60 Hz)
{40 A} |
|
2.5% ± 8 digit (60-500 Hz) {40 A} |
|
1.5% ± 5 digit (50-60 Hz)
{600/1000 A} |
|
2.5% ± 5 digit (60-500 Hz) {600/1000 A} |
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A |
AC response |
rms |
|
Current DC |
Range |
40.00 A, 600.0 A, 1000 A |
Resolution |
0.01 A, 0.1 A, 1 A |
Accuracy |
1.6% ± 6 digit (40 A) |
|
1.5% ± 5 digit (600/1000 A) |
|
Voltage AC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1.5% ± 5 digit (20-500Hz) |
AC response |
rms |
|
Voltage DC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1% ± 4 digit |
|
Resistance |
Range |
400.0 Ω |
|
4000 Ω |
Resolution |
0.1 Ω |
|
1 Ω |
Accuracy |
1% ± 5 digit |
|
Continuity |
|
Inrush |
|
Frequency |
Range |
5.0 - 500.0 Hz |
Accuracy |
0.5% ± 5 digit |
Trigger Level |
10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A |
|
Video del unboxing